Amet Industries use CleanCab Air Filtration units, which have been designed to fit all styles of air conditioning systems & machines. The unit is available in a vertical or horizontal style.
Optional weather protector available. Protects unit from physical damage.
Cabin Pressure Sensor Display Air Pressure, CO² level, Fan Speed & Temperature
CleanCab Mobile APP now Available
Web App for connection with a browser and Bluetooth
Hepa Filter Replacements and Carbon Filter Replacements read more ▷▷
Dust, fibres and other dangerous airborne contaminants are found in a wide range of general Industries. To ensure your operators breathe safe, Cabin Air Filtration Systems should be considered in the following industries:
Construction – from earthworks, demolition, handling insulation, mixing concrete, mortar or plaster, waste handling, abrasive blasting and welding.
Manufacturing – from welding, grinding, abrasive blasting, cleaning, waste handling, recycling, and material (e.g. wood, metal, stone) processing.
Agriculture – from grain handling, pesticides, plant materials, manure; soil handling.
Transport – from material handling (e.g. grain, cement, bulk foods, ore, chemicals, sand).
Waste and Recycling – from handling or processing of waste/recyclable materials.
For machinery operators, silica and asbestos particles need to be controlled by providing a HEPA filtered pressurised cabin. For an airconditioned plant, the cabin doors, windows and any other access points, such as cabling routes, should be well sealed to prevent dust ingress. An industrial cabin air filtration system will provide your operator with clean safe air to breath. The high-pressure HEPA filtration system meets and exceeds ISO23875 requirements, providing a clean airflow for operators.
Workplace exposure standards for airborne contaminants has been updated in 2024. Amet Industries cabin air filter systems, meet the new ISO 23875:2023 regulations. Be sure your workplace conforms to Australian Standards required to keep operators safe around airborne contaminants by ensuring you have operator cabin air filtration systems installed. A cabin air filter can be connected and fitted to most cabins that are able to be made airtight.
PowerCore Edge Blower Motor – Cabin Air Filtration Unit
PowerCore Edge – Operator Cabin Air Filtration Unit/Blower
In a standard air filtration unit, air is drawn in through a PowerCore® filter by a brushless centrifugal blower motor. It is then distributed through the base of the unit to the cabin by a 3 inch adapter.
PowerCore Edge – Industrial Operator Cabin Air Filtration
The unit’s air outlet can be rotated 360 degrees to suit most vehicles or machinery.
Amet Industries use a 3” flex pipe, to duct to the evaporator inlet. Alternatively, it can be ducted directly through the bottom of the unit to the a/c evaporator air inlet.
Carbon and Hepa Filter Replacement for Operator Cabin Air Filter Systems
When a HEPA filter or CARBON filter is used, it is fitted into the base of the unit. Outside air is forced through the Hepa filter or Carbon filter, after being drawn through the PowerCore® filter before being distributed to the Air Conditioning system for a breathe safe workspace.
Amet Industries replace cabin air filters, to keep your cabin air filter system clean.
Cabin air filter replacements are all individually Test Certificated Hepa filters.
CleanCab, released a newly upgraded HEPA filter in December 2025.
This innovative one-piece filter replaces the previous three-piece design, offering several key improvements:
25% more surface area, resulting in improved airflow and extended filter service life.
Each filter is supplied with an individual paper test certificate and a QR code, allowing for easy online access to the certificate for your record-keeping.
The filter is equipped with stainless-steel mesh on both the top and bottom, reducing the risk of handling damage during installation.
The filter is compatible and can easily be retrofitted to all CleanCab pressuriser units.
Cabin Pressure Sensors/Display
Cabin air filter units, essentially pressurise an operator cabin by forcing fresh Hepa filtered air into the breathable space. The pressure inside the cabin is higher than the outside contaminated air. This will force air out of any unsealed gaps in the cabin’s compartment, that previously may have allowed contaminated air from outside, to enter the enclosure. The PowerCore® Edge, dust removal system can recycle breathable air, up to 110 cubic feet per minute, whilst maintaining the correct cabin pressure.
In Cabin Display Monitor Air Filtration System
An industry recommendation is to fit a cabin pressure monitor to warn the operator when the cabin pressure drops below 20PA or rises above 200PA.
Audible & visual warning for the operator
The unit is designed to be easily fitted in any location in the cabin with a simple 2 & 3 wire connection & one sensor tube to monitor outside air pressure.
AUTOMATIC PRESSURE CONTROL is a standard for Cabin Air Filtration.
System Features:
Fan speed %
Cabin Pressure
Door Switch position
System Pressure Alarm
CO² Alarm
Option to change from automatic to manual setting
System configuration
Total system run time
Alarm fault recording
Main Filter run-time & history
Hepa Filter run-time & history
Commission Installation Information
Ability to add features
Cabin Pressure Indicator GREEN: Pressure within acceptable range (OK) RED: Pressure outside acceptable range (FAIL) Touch to mute alarm for 30 minutes CO2 Level Indicator GREEN: Below 900 PPM (OK) YELLOW: 900-1000 PPM (OK, warning level) ORANGE: 1000-2500 PPM (FAIL) RED: Above 2500 PPM (FAIL)
Indicating pressure fail Touch to mute alarm (30 minutes for orange, 10 minutes for red) CO2 Level Value – Current CO2 concentration in PPM Environmental Conditions – Touch to toggle between temperature and humidity Filter Status GREEN: Filters within service life RED: Filter service due Touch to view system and filter run times Info Icon – Touch to view system status and calibration dates Settings – Touch to adjust target cabin pressure and fan speed warning level Fan Speed Indicator GREEN: Normal: Current fan speed percentage RED: Fan speed above warning threshold (potential issue) Cabin Pressure Value – Current cabin pressure in PA
The CleanCab Web App to monitor your cabin pressure from any device
The CleanCab App is a Bluetooth Low Energy web application that communicates with the pressure motor controller. For information on how to connect your device to the motor controller
WORK SAFELY – Safe Work Australia’s Standard for Airborne Contaminants. Workplace exposure standards for airborne contaminants (2024) Cabin Air Quality Standard – ISO 23875:2023 We use CleanCab Filtration System products. Amet Industries Supply, Install and Maintain, Industrial Operator Cabin Air Dust Removal for Vehicles, or fixed cabin environments. Book a cabin air filter system for your cabin environments to keep your operators safe from contaminants, and ensure you conform to the new Australian Standard for Airborne Contaminants Here
Industrial Operator Cabin Air Filters for Vehicles cabin AIR filtER SYSTEM needs Contact Us HERE or CALL NOW